banner112

chigadzirwa

i Series Non-invasive ventilator (Kurara Apnea Kurapa)

Tsanangudzo Pfupi


chigadzirwa tsanangudzo igs

Product Detail

i series OSA_PDF(1)-1 i series OSA_PDF(1)-2

AST (Otomatiki Synchronization Technology)

Tevedzera otomatiki kufema kwemurwere, kunyatso tarisa nguva yekukonzeresa kwemurwere uye kutsiva, uye kupa inoenderana inofemerwa uye yekufemerwa kumanikidzwa;otomatiki sensitivity tekinoroji pasina kuisa nemaoko kunzwisiswa, kuderedza basa rekufema remurwere.

AST

Automatic voltage regulation tekinoroji
Brand new sainzi algorithm, gadzirisa otomatiki kumanikidza, kuona uye kupindura kune dzakasiyana siyana zviitiko zvekufema
Automatic pressure regulation tekinoroji inogona otomatiki uye nemazvo kutarisisa uye kuona 6 mhando dzezviitiko zvekufema senge hypopnea, obstructive apnea, kudzora kuyerera kwemhepo, kuenderera mberi ngonono, kudonha kukuru uye pakati apnea inopindura kumapoka mana ekutanga ipapo.Zvakadai seLow ventilation, obstructive apnea, kudzora kuyerera kwemhepo, kuenderera mberi ngonono.

COMF kudzvinyirira kuburitsa tekinoroji

Yakasimba kudzvinyirira tekinoroji-COMF, ndiyo yedu patent.
Inogona kuve nechokwadi chiyero chekunyaradza, kuteedzera kwepamusoro, kusununguka kubva mukuremerwa nekufema kuburikidza nekiriniki bvunzo uye kuratidzira.

Auto CPAP modhi

Zvinoenderana nekudzivirirwa kwenzira yemhepo, iyo inochinja yakaringana yakanaka yekufambisa mhepo inopihwa otomatiki pakati peiyo yakaderera IPAP uye yepamusoro IPAP, kuvhura nzira yemhepo uku ichivandudza kunyaradza kwevarwere.

Auto Bi-level mode

Zvinoenderana nekudzivirirwa kwenzira yemhepo, inongopa inosiyana yakaringana bi-level kudzvanywa mukati meiyo IPAP neEPA, kuvhura nzira yemhepo uku ichivandudza kunyaradza kwevarwere.

CPAP mode

Iyo mhepo inofefetera inopa kudzvinyirirwa kwakafanana muchikamu chekufema uye chikamu chekufema, zvichibatsira murwere kuvhura nzira yemhepo.

Bi-Level mode

IPAP neEPAP inogona kuiswa zvakasiyana uye inopa nzira mbiri kumanikidza kubatsira varwere kuvhura nzira yemhepo uye kufema zvakanaka.

Parameters

Model

C1

C2

C3

C5

B1

B5

Model

CPAP

CPAP

Auto CPAP

CPAP, Auto CPAP

CPAP, Auto Bilevel

CPAP, Auto CPAP, Bilevel, Auto Bilevel

             

Pressure range

4-20cm H2O

4-20cm H2O

4-20cm H2O

4-20cm H2O

4-25cm H2O

4-30cm H2O

             

Kururama kwepressure

±0.2cm H2O

   

Max.Operation pressure

30cm H2O

   

Ramp nguva

0 kusvika 45 min (5-maminitsi ekuwedzera)

   

COMF pressure relief

1-3 level
     

Humidification level

1-5 mazinga (113 kusvika 185 ℉23 kusvika 85 ℃)

     

Nguva yekusimuka

1-4 mazinga

1-4 mazinga

             

Kuparadzana usiku

HONGU

HONGU

             

Data kuchengetedza huwandu

8G USB dhisiki

   

Kurema

1.72kg

   

Mean sound level

≤30dB